• Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
  • Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
  • Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
  • Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
  • Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
  • Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine

Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine

Warranty: 12 Months/1500 Hours
Type: Basic Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Output Type: AC Three Phase
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 4.0/5
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Our Partner
  • Certifications
  • Company Profile
  • FAQ
Overview

Basic Info.

Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
AC Rotating Exciter
Engine Model
Perkins 1606A-E88tag5
Alternator Model
Stamford, Leroy Somer, Meccalte, Sutong
Control Panel
Deepsea, Comap, Harsen or Smartgen
Fuel Tank Capacity
8-10 Hours (Build-in)
Colour
White, Yellow, Blue, Red, Grey, etc.
Certificate
CE/ISO9001
Options
ATS, Open Type, Trailer Type
Product Name
Diesel Generator
Transport Package
Wooden Case
Specification
2900*1100*1600 mm
Trademark
sutongpower
Origin
China
HS Code
8502120000
Production Capacity
1200set/Month

Product Description

Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine

Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
Standby Power (kVA/kw): 330kVA/264kw
Prime Power (kVA/kw): 300kVA/240kw
Fuel Type: Diesel
Frequency: 50/60Hz
Speed: 1500/1800RPM
Alternator type: Brushless
Powered by: Perkins

 

Product Description

Δ STANDARD CONFIGURATION
√ Industrial PERKINS water-cooled diesel engine
√ Single bearing alternator with insulation class H and IP23
√ Standard CHINT or DELIXI circuit breaker, ABB as an optional
√ Steel base fuel tank with anti-vibration mounting
√ Based 8-10 hours build-in fuel tank
√ 9 dB muffler exhaust system, free-maintenance battery, user's manual
√ Flexible fuel lines and lube oil drain cock
√ Smartgen HM6120 AMF digital controller (ComAp or Deepsea controller as optional)
√ Shrink wrap packing method

PRP: Prime power is available for an unlimited number of annual operating hours in variable
Load applications, in accordance with ISO8528-1.A 10% overload capability is available for a period of 1 hour within 12-hours period of operation

ESP: The Standby power rating is applicable for supplying emergency power in variable load applications for up to 200 hours per year in accordance with ISO8528-1. Overload is not allowed
 
Δ TESTING ITEMS
SUTONG POWER provides a full line of brand new and high quality products. Each and every unit is strictly factory tested before shipment.
Parts faults testing; Fuel tank pressure testing; Bolt tightening torque testing; Painting thickness testing; Voltage bearing and insulation testing; Noise testing; Loading Testing(25%, 50%, 75%, 100%, 110% load to check verify that all control systems, alarm and shut-down protection.

Detailed Photos

Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
Product Parameters

Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
Our Partner

Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine

Certifications

Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine

 

Company Profile

Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine
Prime Power 300kVA/240kw Diesel Generator with Stamford Alternator with Perkins Engine

 

FAQ

Δ FAQ (FREQUENCY ASKED QUESTION)

Question: What's your warranty period?
Answer: Our warranty period is 1 year or 1000 running hours. But with regards to some special projects, we can extend our warranty period.

Question: Does your generators has global warranty?
Answer: Yes, most of our products like Cummins,  Doosan generators enjoy the global warranty service. And the alternators we use like Leroysomer, Stamford, marathon also enjoy the global warranty service, so do not worry about the aftersales service.

Question: Do you accept OEM/ODM service?
Answer: Yes, we accept customization service.

Question: What's your payment terms?
Answer: We can accept T/T 30% in advance, and the balance 70% before shipment or L/C at sight, L/C deferred payment terms or west union. 


Question: What's your delivery time?
Answer: Our normal delivery time is 15-25 working days. Special customized orders may have longer lead time. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now